EKEC4 is a ecmonic design wallbox, internal components we choosing module din-rail product,
such as module design EV charge controller and module contactor,
RFID and DLB functions can be configured according to customer demand,
the products comply with IEC61851-1 standard.
Advantages:
1) Small size wall box,IP 65 IP degree
2) Insise module device are more easy maintain and repair, it using module contactor instead of relay
will have a good electric life and electric clearrance promise, anti-gigh and low temperature
3)Different power 3.5KW/7.3KW/11KW/22KW are same charger housing
4)Can working with a DLB current monitoring device for a DLB function,the device can using
CT for single phase or a RS485 communication kWH meter for both single phase or theree phase
5)Inside controller with Modbus-RTU protocal and RS485

|
|
|
●: Defult |
Selection Code |
|
Model |
|
EKEC4 |
|
|
Case B/C |
Socket type (Case B) |
S |
|
|
Cable type (Case C) Defaut value is 5M,other length can customized |
C |
||
|
Socket & Plug Standard |
American standard Type 1(T1):SAE J1772 |
T1 |
|
|
Europe Standard Type 2(T2)T2:IEC/EN 62196-2 |
T2 |
||
|
China Standard :GB/T20234.2-2015 |
GBT |
||
|
Power |
3.6KW,AC230V±10% 50Hz,16A,1P+N+PE |
3 |
|
|
7.3KW,AC230V±10% 50Hz,32A,1P+N+PE |
7 |
||
|
11KW,AC400V±10% 50Hz,16A,3P+N+PE |
11 |
||
|
22KW,AC400V±10% 50Hz,32A,3P+N+PE |
22 |
||
|
Protection |
Configuration Device |
|
|
|
Overtemperature Protection |
Chip Overtemperature Protection |
● |
|
|
Residual Current protection |
RCMU |
IEC62955 standard AC30mA+DC6mA Residual |
● |
|
PEN falut protection |
Relay |
Using for UK TNS System for PEN loss protection |
0 |
|
RFID |
RFID module with card |
Support swape RFID card stop and start charging |
1 |
|
Electronic Lock |
Electronic Lock |
Support lock the plug when charging |
2 |
|
DLB |
Current Transformer |
CT Connected in Main circuit only for single phase |
3 |
|
kWH meter (out Station) |
kWH meter Connected in Main circuit both for |
4 |
|
|
OV&UV protection, Over current |
KwH meter (in station) |
a kWM meter with MID certificate |
6 |
|
Surge Protective |
SPD |
Only for single phase |
7 |
|
Emergency Stop |
Emergency stop switch |
|
8 |
Note: Model Selection Example: EKEC4-S-T2-22-12
|
EV charging modes |
Mode 3 charging |
|
Rated voltage |
AC 240V ±10%, AC 420V ±10% |
|
Rated current |
Max 16A, Max 32A |
|
Rated frequency |
50Hz |
|
Over voltage category (OVC) |
OVC III |
|
Insulation resistance |
R > 1 MΩ |
|
AC withstand voltage |
1430V |
|
Impulse dielectric withstand voltage (1,2 μs/50 μs) (Uimp) |
4kV |
|
Protection against electric shock |
Class I |
|
Electrical life (contactcor) |
100,000 |
|
Electrical life (Interface) |
100,000 |
|
Standby Power Consumption |
<8W |
|
Type of EV connection |
Case B (Socket version) / Case C (Cable Version) |
|
universal interface |
T1: SAE J1772, T2: IEC/EN 62196-2, GB/T: 20234.2-2015 |
|
Pollution degree |
PD 3 |
|
IP protection class |
IP54 |
|
Altitude during operation (m) |
<2000m |
|
Altitude of test laboratory |
<50m |
|
Work Humidity |
3%~95% |
|
Operation temperature |
-25℃— 40℃ |
|
Colling |
Natural Air Cooling |
|
Mounting method |
mounted on walls, poles or equivalent positions: |
|
Normal environmental conditions |
indoor use; Outdoor use |
|
Product Dimension (mm) |
357*245*123 |
|
Installation Dimension (mm) |
180*280 |
|
The AC charger require external MCB for overload protection and short-circuit protection to be installed in upstream distribution box |
|