EKEPC2-C/S EPC Charge Controller Maximum Output Current Value Setting Via RS485 Communication

Publish Time: Author: ETEK Electric Visit: 242

Introduing how to change the EKEPC2-C/S EVSE EPC controller PWM value via RS485 communication

1) Communicate with the EKEPC2 controller through RS485 and send a command to change the PWM value of the output current to the register address 109 (maximum output current duty cycle) to change the maximum output current value

2The maximum output current value to PWM value is calculated as follows
    Output current to PWM value: 60A or less,
    PWM value= Output current value/0.6*100
    For example, 32A = 32/0.6 x 100 = 5333

    So 32A sets the 109 register address value to 5333

Hot Products

Inquiry Basket()
Send An Inquiry

Get in Touch

×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All