EKEPC3-C/S EV Charging Station OCPP protocal Controller

EKEPC3-C/S EV Charging Station OCPP protocol Controller

The EKEPC3 evse controller is OCPP1.6J protocol with WIFI, 2G-4G, ethernet net communication,which can communication with charger with a OCPP1.6J protocol backend,also we can support a RS485 communication for kWH meter, the controller addtional functions including:non-contact IC card connection module, residual current monitoring unit, DLB management, LCD dislay, kWM Meter,electronic lock, external emergency stop pushbutton, etc. These function must be NOTED when ordering.

Inquire NOW PDF
EKEPC3-C/S EV Charging Station OCPP protocal Controller

EKEPC3-C/S EV Charging Station OCPP protocol Controller

Inquire NOW PDF

Product Profile

The EKEPC3 smart Ccharger  controller is OCPP1.6J protocol with WIFI, 2G-4G, ethernet net communication,which can communication with charger with a OCPP1.6J protocol backend,also we can support a RS485 communication for kWH meter, the controller addtional functions including:non-contact IC card connection module, residual current monitoring unit, DLB management, LCD dislay, kWM Meter,electronic lock, external emergency stop pushbutton, etc. These function must be NOTED when ordering.

Technical Data

Model EKEPC3-C/S
Mode Mode 3 charging
Operating Voltage 32A, 1-32A adjustable
Outputthe PWM Signal  Max:32A, 1-32A adjustable
Basic Function 2:Overtemperature protection
Additional Function 1:RCMU DC6mA leakage monitoring with a axuliary device of RCMU
2:Swape RFID card/NFC start or stop charging function with a axuliary device of RFID module and cards
3:LCD display function with a axiliary device of LCD screen
4:Elecronic lock function with a device Electronic lock
5:DLB function with a axuliary device of CT or kWH meter
6:Overvolatge&Undervoltage protection
7:Over current protection
8:voltage,current,Power for real time monitoring with a axuliary of kWH meter
9:Emergency Stop function with a axuliary device of Pushbutom switch
Protocol(communication) -OCPP1.6J Protocol,Wifi,Ethernet communication
-Modbus-RTU protocal and RS485 communication only for kWH meter
Output Auxiliary Voltage DC12V/100mA\DC5V/100mA
Ambient Temperature -40℃-+50℃
Humidity <=85%
Colling Method Natural cooling
Installation Method Din-Rail mounted

Dimensions

Recommend Products

Inquiry Basket()
Send An Inquiry

Get in Touch

×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All