EKL6-100B Type B RCCB

EKL6-100B Type B RCCB

EKL6-100B is a EV charging station using type B RCCB with TUV Rheinland, CE, UKCA, CB certificated, maxmum current is 100A, Ambient temperature is -25℃-+55℃

Inquire NOW PDF
EKL6-100B Type B RCCB

EKL6-100B Type B RCCB

Inquire NOW PDF

Product Profile

EKL6-100B  B type RCCB is a electromagnetic type RCD, it can protection B type wave form of the earth leakage sensed and

also have DC smooth direct residual currents, according to IEC61851 standard, it can working as the EV Charging station RCCB,

we normally using 3.7kW (1P+N 25A 30mA), 7.3KW (1P+N 40A 30mA). 11KW (3P+N 25A 30mA), 22KW (4P+N 40A 30mA)

Technical Data

Electrical Features
Mode Electromagnetic
Type (wave form of the earth leakage sensed) B
Rated current In 25,40,63,80,100A
Poles 2P,4P
Rated voltage Ue 2P 240V~, 4P 415V~
Insulation voltage Ui 500V
Rated frequency 50/60Hz
Rated residual operation current (I△n) 30mA
Rated residual making and breaking capacity (I△m) 500A(In≤40A), 10ln(In> 40A)
Short-circuit current Inc= I△c 10,000A
SCPD fuse
Break time under I△n ≤0.1s
Rated impulse withstand voltage (1.5/50) Uimp 4000V
Dielectric test voltage at ind.Freq. for 1min 2.5kV
Electrical life 2,000 Cycles
Mechanical life 4,000 Cycles

 

 

Installation
Contact position indicator Yes
Protection degree IP20
Ambient temperature (with daily average ≤ 35℃) -25℃~+40℃
Storage temperature -25℃~+70℃
Terminal connection type Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable 35mm² 18-3AWG
Terminal size top/bottom for busbar 35mm² 18-3AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection Power supply in both directions

 

 

Tripping Current Range
Lagging Angle I△n> 0.01A I△n> 0.01A
0.35I△n≤I△≤1 4I△n 0.35I△n≤I△≤2I△n
90° 0.25I△n≤I△≤1.4I△n 0.25I△n≤I△≤2I△n
135° 0.11I△n≤I△≤1 4I△n 0.11I△n≤I△≤2I△n

 

 

Tripping Current Range
Detectable wave form Pulsating direct current sensitive Surge current proof

B class

Tripping is ensured for sinusoidal AC
residual currents pulsed DC residual
currents, alternating residual
sinusoidal currents up to 1000Hz,
pulsating direct residual currents and
for smooth direct residual currents,
whether applied suddenly or
increasing slowly.

 

They react to AC and pulsating DC
fault current which reach 0 or almost
0 within one time period of the
mains frequency.

RCCB'S surge capacity.
Not tripping at standardized 8/20 US
surge-current waves acc.to VDE 0432
Part 2 with surge current values of up
to 250A.

Dimensions

Circuit Diagram

 

 

Overall and Installation Dimension (mm)

Product selection form

Poles Rated Current (A) Sensitivity
30mA 100mA 300mA
1P+N 16A EKL6-100B-1N1630 EKL6-100B-1N16100 EKL6-100B-1N16300
25A EKL6-100B-1N2530 EKL6-100B-1N25100 EKL6-100B-1N25300
32A EKL6-100B-1N3230 EKL6-100B-1N32100 EKL6-100B-1N32300
40A EKL6-100B-1N4030 EKL6-100B-1N40100 EKL6-100B-1N40300
63A EKL6-100B-1N6330 EKL6-100B-1N63100 EKL6-100B-1N63300
80A EKL6-100B-1N8030 EKL6-100B-1N80100 EKL6-100B-1N80300
100A EKL6-100B-1N10030 EKL6-100B-1N100100 EKL6-100B-1N100300
3P+N 16A EKL6-100B-3N1630 EKL6-100B-3N16100 EKL6-100B-3N16300
25A EKL6-100B-3N2530 EKL6-100B-3N25100 EKL6-100B-3N25300
32A EKL6-100B-3N3230 EKL6-100B-3N32100 EKL6-100B-3N32300
40A EKL6-100B-3N4030 EKL6-100B-3N40100 EKL6-100B-3N40300
63A EKL6-100B-3N6330 EKL6-100B-3N63100 EKL6-100B-3N63300
80A EKL6-100B-3N8030 EKL6-100B-3N80100 EKL6-100B-3N80300
100A EKL6-100B-3N10030 EKL6-100B-3N100100 EKL6-100B-3N100300

Recommend Products

Inquiry Basket()
Send An Inquiry

Get in Touch

×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All