ETEC EKEC5 Basic EV Charger
ETEC EKEC5 Basic EV Charger

ETEC EKEC5 OCPP Protocol EV Charger | 3.6kW/7.3kW, DLB, RFID

EKEC5 basic type home EV charger can both wall/post mounting,support single phase 3.6kW 7.3kW charging,and DLB, RFID functions optionls.

Inquire NOW PDF

ETEC EKEC5 OCPP Protocol EV Charger | 3.6kW/7.3kW, DLB, RFID

Inquire NOW PDF

Product Profile

EKEC5 basic type internal is a EVSE EV charging PCB board

 

Advantages:

1)Nice and samll appearance design and can be customized with different shell colors

2)With overload protection, over voltage protection, under voltage protection, short, circuit protection, over temperature protection, emergency stop and other functions

3)Can add a RFID module and cards,using card start/stop charging,card number can customized,also can add new by customer themself(No billing card)

4)Can working with a DLB current monitoring device for a DLB function,the device can using CT

Model Preparation Meaning

 

 

●: Defult
Green: Simple Choice
Blue: Multiple Choice

Selection Code

Model

 

 

EKEC5

Net Mode

Ocpp1.6J Protocal

Suppport Ethernet/Wifi/4G/3G/2G
Communication using EKEPCB2 Controller

Case C

Cable type (Case C) Defaut value is 5M,other length can customized

Socket & Plug Standard

American standard Type 1(T1): SAE J1772

T1

Europe Standard Type 2(T2)T2: IEC/EN 62196-2

T2

China Standard: GB/T20234.2-2015

GBT

Power

3.6KW,AC230V±10% 50Hz,16A,1P+N+PE

3

7.3KW,AC230V±10% 50Hz,32A,1P+N+PE

7

Protection

Configuration Device

 

 

Overtemperature Protection

Chip Overtemperature Protection

Residual Current protection

RCMU

IEC62955 standard AC30mA+DC6mA Residual
current protection (Should at least installation a
Type A RCD in front of Charger)

PEN falut protection

Relay

Using for UK TNS System for PEN loss protection

0

RFID

RFID module with card

Support swape RFID card stop and start charging

1

DLB

Current Transformer

CT Connected in Main circuit only for single phase

3

kWH meter (out Station)

kWH meter Connected in Main circuit both for
single phase or three phase, other brand meter
using pls checking the Charger usage manual

4

Emergency Stop

Emergency stop switch

 

Box Color

 

Silver color box

S

Green color box

G

Red color box

R

Note: Model Selection Example: EKEC5-T2-7-1-S

 

Technical Data

EV Charging Modes

Mode 3 charging

Rated Voltage

AC 240V ±10%

Rated Current

Max 32A

Power

Max:7.3KW

Rated frequency

50Hz

Over voltage category (OVC)

OVC III

Insulation resistance

R > 1 MΩ;

AC withstand voltage

1430V

Impulse dielectric withstand voltage (1,2 μs/50 μs) (Uimp)

4kV

Protection against electric shock

Class I

Electrical life (contactcor)

100,000

Electrical life (Interface)

100,000

Standby Power Consumption

<8W

Ocpp1.6J Protocal

Suppport Ethernet/Wifi Communication

Type of EV connection

Case C(Cable Version)

universal interface

T1:SAE J1772,T2:IEC/EN 62196-2,GB/T:20234.2-2015

Pollution degree

PD 3

IP protection class .

IP54

Altitude during operation (m)

<2000m

Altitude of test laboratory

<50m

Work Humidity

3%~95%

Operation temperature:

-25℃— 40℃

Colling

Natural Air Cooling

Mounting method

mounted on walls, poles or equivalent positions

Normal environmental conditions

indoor use;Outdoor use

Product Dimension (mm)

357*245*123

Installation Dimension (mm)

180*280

The AC charger require external MCB for overload protection and short-circuit protection to be installed in upstream distribution box

 

Dimensions

Recommend Products

Inquiry Basket()

Get in Touch

×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All