DLB Current Monitoring Current Using kWH Meter for EKEPC2/EKEPCB3 Controller

DLB Current Monitoring Current Using kWH Meter for EKEPC2/EKEPCB3 Controller

ADL200,ADL400 kWH meter

Inquire NOW PDF
DLB Current Monitoring Current Using kWH Meter for EKEPC2/EKEPCB3 Controller
DLB Current Monitoring Current Using kWH Meter for EKEPC2/EKEPCB3 Controller

DLB Current Monitoring Current Using kWH Meter for EKEPC2/EKEPCB3 Controller

Inquire NOW PDF

Product Profile

The kWH meter using as the DLB current monitoring device, installation at the mian circuit of the home,

via rs485 communication with controller via wire connected, controller will read the real time of DLB current,

if the  circuit current exceed the DLB current setted value,controller will reduce the charging current still stop charging

Technical Data

EKEPCB2 Model 3 EV Charge Controller
Model EKEPCB2-C/S
Mode Mode 3 charging
Operating Voltage AC230V±10%,50Hz
Outputthe PWM Signal Max: 32A, 1-32A adjustable
Basic Function 1:RCMU DC6mA leakage monitoring
2:Overtemperature protection
3:Overvolatge&Undervoltage protection
4:Over current protection
5:voltage,current,Power for real time monitoring
Additional Function 1:Swape RFID card/NFC start or stop charging function with a axuliary
   device of RFID module and cards
2:LCD display function with a axiliary device of LCD screen
3:Elecronic lock function with a device Electronic lock
4:DLB function with a axuliary device of CT or kWH meter
5:Emergency Stop function with a axuliary device of Pushbutom switch
Protocol(communication) -OCPP1.6J Protocol,Wifi,Ethernet communication
-Modbus-RTU protocal and RS485 communication only for kWH meter
Output Auxiliary Voltage DC12V/100mA\DC5V/100mA
Ambient Temperature -40℃-+50℃
Humidity <=85%
Colling Method Natural cooling
Installation Method PCB mounted

 

 

EKEPCB3 Model 3 EV Charge Controller
Model EKEPCB3-C/S
Mode Mode 3 charging
Operating Voltage AC400V±10%, 50Hz
Outputthe PWM Signal Max: 32A, 1-32A adjustable
Basic Function 1:RCMU DC6mA leakage monitoring
2:Overtemperature protection
3:Overvolatge&Undervoltage protection
4:Over current protection
5:Voltage,current,Power for real time monitoring
Additional Function 1:Swape RFID card/NFC start or stop charging function with a axuliary device of RFID module and cards
2:LCD display function with a axiliary device of LCD screen
3:Elecronic lock function with a device Electronic lock
4:DLB function with a axuliary device of CT or kWH meter
5:Emergency Stop function with a axuliary device of Pushbutom switch
Protocol (communication) -OCPP1.6J Protocol,Wifi,Ethernet communication
-Modbus-RTU protocal and RS485 communication only for kWH meter
Output Auxiliary Voltage DC12V/100mA\DC5V/100mA
Ambient Temperature -40℃-+50℃
Humidity <=85%
Colling Method Natural cooling
Installation Method PCB mounted

Dimensions

DLB Function Application Legend

Recommend Products

Inquiry Basket()
Send An Inquiry

Get in Touch

×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All